OBD-II trouble code · Powertrain (engine and transmission)
P0131 O2 Sensor Circuit Low Voltage Bank 1 Sensor 1
Your upstream oxygen sensor on bank 1 is reporting a voltage that stays too low. This could be a real lean condition or a sensor or wiring problem.
My bank 1 upstream oxygen sensor keeps saying I'm lean. Let's figure out whether it's the sensor or a real leak.
— FRED, speaking as your car
What P0131 means
P0131 sets when the bank 1 sensor 1 signal stays below its expected minimum for a set time. On traditional sensors, low voltage indicates lean exhaust, so a real lean condition, vacuum leak, or exhaust leak can cause it, along with a failed sensor or shorted wiring. Wide-band sensors use different signaling, and thresholds vary by make.
Common symptoms
- Check-engine light on
- Poor fuel economy
- Hesitation or rough idle
- Possible lean codes
- Failed emissions test
- Often no other symptoms
Likely causes (most likely first)
- Faulty upstream O2 sensor
- Signal wire shorted to ground
- Exhaust leak before the sensor
- Vacuum leak causing real lean condition
- Low fuel pressure
- Contaminated sensor
What you can check yourself
- Check for P0171 or other lean codes
- View fuel trims; high positive trims suggest a real lean condition
- Inspect for exhaust leaks near the sensor
- Inspect wiring for chafing or shorts
- Briefly snap the throttle while watching live O2 data; it should respond
- Replace the sensor if engine conditions are normal
FRED reads freeze frame and live data, so you can see what the engine was doing when P0131 set, before you buy any parts.
Typical repair costs
| Repair | Typical range |
|---|---|
| Replace upstream O2 sensor | $150–$400 |
| Repair exhaust leak | $100–$500 |
| Repair vacuum leak | $50–$400 |
| Repair wiring | $100–$300 |
Typical US independent-shop ranges, parts and labor. Your price varies by vehicle, region and shop.